Allen-Bradley 2094-BMP5-S Kinetix 6000 Axis Module

Model:2094-BMP5-S

$1,849.99
Product Code: 2094-BMP5-S
Reward Points: 200
Availability: In Stock
Features:

- Brand: Allen-Bradley 

- Rockwell Automation

- Manufacturer Part Number: 2094-BMP5-S

- Series: Kinetix 6000 Axis Module

Input Supply Voltage Range: 324-528V rms, 3-phase

Nominal Voltage: 360 / 480V

Voltage Category: 400V

Continuous Output Current (rms): 2.8 A

Continuous Current (sine) 0-pk: 4.0 A

Peak Current (rms): 4.2 A (Series A), 7.0 A (Series B and C)

Peak Current (0-pk): 5.9 A (Series A), 9.9 A (Series B and C)

Continuous Power Output: 1.8 kW

Short-Circuit Current Rating: 200,000 A (rms) symmetrical

Integrated Safe Torque-Off (STO) Feature: Certified to ISO 13849-1 PLe/SIL 3


Safety Certification: 

The STO feature is certified to ISO 13849-1 PLe (Performance Level e) and Safety Integrity Level (SIL) 3. These are international standards that assess the reliability and effectiveness of safety functions. Achieving such high levels of safety certification means that the 2094-BMP5-S provides a robust and dependable safety mechanism.


EN954-1, Category 3 Standard: 

To meet the EN954-1 Category 3 standard, an external safety relay may need to be added. This standard is part of the European safety standards and is associated with safety-related control systems. It ensures that safety functions meet specified performance levels.


Circuit Trip Response: 

The STO feature responds to a circuit trip or an emergency stop by safely removing torque from the motor. This is a crucial safety function, especially in industrial settings where sudden stops or emergency shutdowns can occur. By cutting off torque, it prevents the drive from attempting to restart automatically.


Preventing Unwanted Operation: 

The primary purpose of STO is to prevent unwanted or unintended machine operation after an emergency event. This helps reduce the risk of accidents, injuries, and damage to equipment.


Risk Reduction:

 The STO feature contributes to lowering the risk and danger to properties and the people involved in operating and troubleshooting the machinery. It ensures that the system remains in a safe state until authorized personnel can assess and address the situation.